Volume 22, Issue 158 (2025)                   FSCT 2025, 22(158): 227-237 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

karimi F, Azizi M, MOEINI S, Karimi M, Moogouei R. Microencapsulation of canthaxanthine with electrospray and optimizaing processing papameters toward efficiency encapsulation by response surface methodology. FSCT 2025; 22 (158) :227-237
URL: http://fsct.modares.ac.ir/article-7-61694-en.html
1- Department of Food Science and Technology, Islamic Azad University North Tehran branch,Tehran, Iran , karimi.f258@gmail.com
2- Department of food science and Technology, Tarbiat Modares university, Tehran, Iran
3- .Department of Food Science and Technology, Islamic Azad University North Tehran branch,Tehran, Iran
4- Department of Textile Engineering, Amirkabir University of Technology, Tehran, Iran
5- Department of Enviromental planning, Management and Education, Islamic Azad University North Tehran Branch, Tehran, Iran
Abstract:   (109 Views)
This study showed the potential of the electrospinning (in this case electrospraying) technique to produce whey protein concentrate (WPC) micro and nanocapsules for applications in the encapsulation of canthaxanthin. The results showed that the solution concentration, feed solution flow rate and applied voltage had a direct effect  on the encapsulation efficiency. by increasing of the solution concentration, feed solution flow rate and applied voltage, the encapsulation efficiency increased. The results showed that solution concentration was the most effective factor in electrospraying, because its scale estimate was highest. According to the results of analysis of variance (ANOVA) for this model, the regression model suggested a significant value for both linear and quadratic terms at P < 0.05. Also in order to obtain 0.93% encapsulation efficiency, optimum  point was found at the emulsion concentration of 39.4%, feed solution flow rate of 12.2 ml/min, applied voltage of 17.5 kV, and 17.1cm distance between needle tip and collector.
Full-Text [PDF 456 kb]   (81 Downloads)    
Article Type: Original Research | Subject: Antioxidants
Received: 2022/05/21 | Accepted: 2023/01/1 | Published: 2025/03/21

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.