Volume 20, Issue 140 (2023)                   FSCT 2023, 20(140): 193-203 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Salehi F, Inanloodoghouz M. Effects of ultrasonic intensity and duration on the apparent viscosity, consistency coefficient, and flow behavior index of guar gum solution. FSCT 2023; 20 (140) :193-203
URL: http://fsct.modares.ac.ir/article-7-72215-en.html
1- Associate Professor, Department of Food Science and Technology, Bu-Ali Sina University, Hamedan, Iran , fs1446@yahoo.com
2- MSc Student, Department of Food Science and Technology, Bu-Ali Sina University, Hamedan, Iran
Abstract:   (106 Views)
Guar gum is a biopolymer that is used in the food industry as a thickener, stabilizer, and edible coating. The aqueous solution of this gum has high viscosity and pseudoplastic behavior. This research aimed to analyze the impacts of sonication at different intensities (0, 75, and 150 W) and time intervals (0, 5, 10, 15, and 20 min) on the viscosity and rheological behavior of guar gum solution. The results showed that the apparent viscosity of guar gum solution (untreated sample) reduced from 0.070 to 0.030 Pa.s with increasing shear-rate from 12.2 s-1 to 134.5 s-1. Also, the apparent viscosity of guar gum solution reduced from 0.046 to 0.021 Pa.s with increasing the sonication time from 0 to 20 min (shear-rate=49 s-1 and power= 150 W). Various rheological equations (Power law, Bingham, Herschel-Bulkley, Casson, and Vocadlo) were employed to fit the empirical values, and the findings of the current study confirmed that the Power law model was the best fit to explain the flow behavior of guar gum solution s. The consistency coefficient of guar gum solution significantly reduced from 0.202 Pa.sn to 0.063 Pa.sn (p<0.05) with increasing sonication time from 0 to 20 min. Furthermore, the consistency coefficient of guar gum solution decreased considerably (p<0.05) while the ultrasonic power enhanced. The flow behavior index of guar gum solution increased significantly (p<0.05) while the intensity and duration of ultrasound treatment increased.
Full-Text [PDF 399 kb]   (111 Downloads)    
Article Type: Original Research | Subject: Hydrocolloids, emulsion
Received: 2023/11/1 | Accepted: 2023/12/18 | Published: 2023/10/2

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.